ǰ Ư¡.
XL Microwaves Analyze-R
, Model 2261, is an affordable, easy-to-use, application specific, Spectrum
Monitor / Analyzer for ISM and U-NII applications in both the 2 & 5 GHz
bands. The Analyze-R is designed for those doing site spectrum monitoring and
analysis, surveying, installing, maintaining, and troubleshooting the latest
wireless communication systems in the unlicensed ISM / U-NII bands. This unique
instrument is designed for field operation and is a fraction of the cost of a
full-featured general-purpose spectrum analyzerand far easier to
use! | |
The Analyze-R has an intuitive
interface and provides both frequency and amplitude information across an entire
100 MHz U-NII band. Resolution bandwidth is 1 MHz and the amplitude range spans
-100 dBm to –30 dBm (nom./either peak or average modes). The Analyze-R employs
a monochrome backlit LCD display thats easy to read in high or low ambient
light conditions. The display operates in real time and, when in band sweep
mode, displays 101 1-MHz channels across a 100 MHz band. An adjustable on-screen
marker provides specific measurement of amplitude and frequency, allowing
precise evaluation of signals. In single frequency mode, the display switches
from a graphic display to a numeric display to show a specific frequency and its
associated RSL power in dBm. This mode is most useful when aligning the antenna
for a terrestrial point-to-point link or for monitoring a specific frequency
channel.
GENERAL SPECIFICATIONS:
RECEIVER:
- Selectable Frequency Bands:
- Band 1 (ISM): 2.400–2.484 GHz ( 85,
1-MHz-wide channels);
- Band 2 (U-NII-1): 5.150–5.250 GHz
(101, 1-MHz-wide channels);
- Band 3 (U-NII-2): 5.250–5.350 GHz
(101, 1-MHz-wide channels);
- Band 4 (ISM/U-NII-3): 5.725–5.875 GHz
(3-101, 1-MHz-wide channels, L/M/H).
- (L)ow: 5.725–5.825 GHz;
- (M)edium: 5.750–5.850 GHz;
and,
- (H)igh: 5.775–5.875 GHz.
- Bandwidth: 2 MHz.
- Sensitivity: -100 dBm nom.
- Amplitude: ±1.5 dBm (from -40 dBm to
-90 dBm).
- Overload Point: -30 dBm nom.
- Damage Level: +10 dBm.
- Frequency Stability: 2 x
10-5 (temperature 0°C to 50°C).
LCD DISPLAY:
- Graphic Display: 64 x 128 pixel LCD,
backlit. Displays frequency (101, 1 MHz points)(L/M/H in Band 4) and power (56,
1.25 dBm points)(peak hold or average).
- Graphic Resolution: Power: 1.25
dB/pixel; Frequency: 1 MHz/pixel.
- Graphic Dynamic Range: -35 dBm to
-102.9 dBm, graphically displayed.
- Numeric Dynamic Range: -24.1 dBm to
-103.8 dBm, numerically displayed.
- Update Time: 300 ms (2 ms measure, 1
ms compute per channel x 100 channels).
- Marker: Marker is tuned with a front
panel knob. Marker frequency and power intercept are displayed at the top of the
LCD.
- Marker Resolution: 0.1 dB (power), 1
MHz (frequency).
LEDs:
- Low Battery Indicator: LED, ON when battery has
approx. 15 min. left.
- LED Status Indicators: LOW BATTERY, CHARGED BATTERY,
AC MAINS (charger connected), BAND SWEEP, SINGLE FREQUENCY, PEAK HOLD, AVERAGE,
BAND 1 (2.400–2.484 GHz), BAND 2 (5.150–5.250 GHz), BAND 3 (5.250–5.350 GHz),
BAND 4 (5.725–5.875 GHz; L/M/H). Record-R (recording data), MEMORY OK, GPS
LOCK.
Record-R DATA LOGGING
SPECIFICATIONS:
- Data Recorded: Received Signal Level
(in dBm per channel / peak or average), Frequency, Longitude, Latitude, Date
& Time (UTC), Model Number & Serial Number of unit.
- Max. No. of Records: 250 single
frequency records (32 bytes ea.) or 62 band sweep records (128 bytes ea.) or
some combination, 8K Bytes total memory.
- Record Time to Memory: Band sweep:
< 2 seconds, single frequency: approx. 20 milliseconds.
- Data Format: CSV (comma-separated
variable).
- Downloading Records: Records are
downloaded, thru RS-232-C or USB 'B' rear panel connectors.
- Download Baud Rate: 9600 Baud.
- Software (included): Log View-R
Data Log Utility software for Windows 95/98/2000/XP operating systems. This
software allows a remote computer to download, display, and save data records
and clear the instrument's memory.
GPS:
- Frequency: L1 (1575.42 MHz), C/A code (SPS),
8-channel cont. tracking, 32 correlators.
- Position Accuracy: ±2 meters CEP (50%).
- Timing Accuracy: ±95 nano-seconds.
- Position Fix Update: 1 second.
- Time to Lock:
- Cold Start: <130 seconds (90%);
- Warm Start: <45 seconds (90%);
- Hot Start: <20 seconds (90%).
- Reacquisition Time: <2 seconds (90%) after loss
of signal.
BATTERY CHARACTERISTICS:
- Operating Time (approx.): 5–6 hours
continuous @ 25єC (77єF). Low Battery indicator LED ON when approx. 1 hour
operating time remains.
- Charge Time (approx): 3 hours.
- Manufacture: Panasonic.
- Manuf. Part No.: LCS-2312NC,
Rechargeable Sealed Lead/Acid Battery.
- Nominal Voltage: 12 VDC.
- Nominal Capacity: 2.3 Ah.
- Capacity affected by
Temperature:
- 40°C (104°F) 102%
- 25°C (77°F) 100%
- 0°C (32°F) 85%
- -15°C (5°F) 65%
- Self-Discharge @ 25°C:
- Capacity after 3 month storage-
90%
- Capacity after 6 month storage-
80%
- Capacity after 12 month storage-
60%
BATTERY
CHARGER:
- AC MAINS Input: 90–264 VAC / 47–63
Hz.
- AC MAINS Connector: IEC-320,
3-conductor. Conforms to IEC 320-3:1987/EN 60 320.
- DC Output: 15 VDC / 1 A.
- DC Connector: 5.5 mm x 2.1 mm Barrel
Power connector, 5-foot cord.
- Dimensions (HxWxD): 33 mm x 51 mm x 86
mm (1.3 in. x 2.0 in. x 3.4 in.).
- Operating Temperature: 0єC to 40єC
(32єF to 104єF).
MECHANICAL:
- Power: DC, self-contained 12 VDC, 2.3 Ah,
Rechargeable Sealed Lead/Acid Battery.
- Weight:
- Net: <3.2 kg (7 lbs.) per unit (inc. Battery and
Weather-resistant Instrument Back-pack).
- Shipping: 5 kg (11 lbs.).
- Dimensions (HxWxD): 89 mm x 213 mm x 333 mm (3.5
in. x 8.375 in. x 13.1 in.).
- Connectors:
- RF In: Type 'N' female.
- Battery Charger In: 5.5 mm x 2.1 mm rearpanel Power
jack (15 VDC/1 A, center pin positive).
- RS-232-C: DB-9 female (rear panel).
- USB: USB type B female (rear panel).
ENVIRONMENTAL
Designed to meet EN 61010-1 (IEC 1010-1),
Specifically:
- Temperature:
- Operating: -15°C to 50°C (5єF to 122єF).
- Storage: -40°C to 71°C (-40єF to 160єF) without
battery. Battery: -15°C to 40°C (5єF to 104єF).
- Battery Charging: 0°C to 40°C (32°F to
104°F).
- Relative Humidity: 95% ±5% 10°C to 30°C; 75% ±5% to
40°C; 45% ±5% above 40°C.
- Altitude: 4600 meters (15,000 feet).
- Burn In: Failure-free burn in of no less than 100
hours at 40°C.
- Pollution Degree: 1 (no pollution)(EN
61010-1/3.7).
- Transient Overvoltage: Installation Category II (EN
61010-1/J).
SUPPLEMENTAL
SPECIFICATIONS:
- Warranty: One Year Limited Warranty.
- Montreal Protocol: Nil Return.
- ISO 9000: XL Microwave's Quality System is
registered and certified by TUV Essen to the Quality Assurance Standards of ISO
9001.
- CE (European Union): EN 55011:1998 w/A1:1999, Group
1, Class B (emissions); EN 61326-1:1997 w/A1:1998 (immunity).
ACCESSORIES FURNISHED:
- One (1) Operating Manual with User Information
Card.
- One (1) Weather-resistant Instrument
Back-pack.
- One (1) Battery, Rechargeable, 12 VDC/2.3 Ah, Sealed
Lead/Acid Batery.
- One (1) Battery Charger, AC MAINS powered, 90–264
VAC; with IEC-320 Input connector.
- One (1) AC MAINS power cord (conforms to IEC
320-3:1987/EN 60 320 and CEE color coding) UL listed type SVT, 3-conductor Vinyl
with NEMA, type 5-15p plug and IEC 320-3:1987/ EN 60 320 end termination.
- One (1) Cable: Coax Cable Assembly, N-type (male) to
N-type (male), 3-meters long.
- One (1) Cable: RS-232 Cable Assembly, D-sub 9-pin
(male) to D-sub 9-pin (female), 3-meters (9.84 ft.).
- One (1) Cable: USB Cable Assembly, USB 'A' (male) to
USB 'B' (male), 2-meters (6.56 ft.).
- One (1) Floppy disk(s) copy of Log View-R, data
logging utility software.
OPTIONAL ACCESSORIES
AVAILABLE
- Opt
Description
- 320 Spare Battery, 12 VDC/2.3 Ah Rechargeable
Sealed Lead/Acid.
- 321 Portable Battery Charger, AC MAINS powered
(90–264 VAC/47–63 Hz; IEC-320 Input connector) w/AC cord & Adapter.
- 336 Weather-Resistant Instrument
Back-Pack
- 326 Case: Watertight, Airtight, Corrosion Proof,
Dust Proof, Crush Proof, for severe enviromental conditions.
- Holds (1) 2200, 19" x 14" x 7-3/4" (L x
W x D).
- 328 Cable: Coax Cable Assembly, N-type (male) to
N-type (male), 3-meters long.
- 340 Cable: RS-232 Cable Assembly, DB-9
(male/female), 3-meters long.
- 341 Cable: USB Cable Assembly, 'A' (male) to 'B'
(male), 2-meters long.
- 335 Extra Operating Manual.
The Analyze-R also contains XLs
Record-R Data Logger, with embedded GPS receiver, for recording specific single
frequency information or an entire 100 MHz ISM / U-NII band sweep. Recorded
information includes frequency, peak or average power, longitude, latitude, and
UTC date & time. Recording a Band Sweep will yield individual 1 MHz-wide
peak or average power steps through the entire 100 MHz band along with location
and date/time information. The instrument includes both RS-232 and USB
interfaces. The Log View-R companion software (included) provides a virtual
graphic display of the original recorded sweep including software marker for
reading power/frequency values. The Log View-R is used for transferring
information from the instrument to a PC for saving, viewing, analyzing,
archiving, and printing of the recorded data.
Background To address the increasing use of the unlicensed ISM and U-NII
Bands for WLAN, business-to-business and last-mile (short-haul) point-to-point
and point-to-multipoint applications, XL Microwave has introduced the Model
2261, Analyze-R. This unique instrument allows you to quickly acquire and
capture accurate test measurements for site analysis of interference as well as
optimum antenna location. Additionally, the Analyze-R provides a versatile test
solution for accurate antenna alignment.
Because U-NII systems often operate
slightly above the ambient signal noise level, and ISM transmissions are allowed
greater EIRP power than U-NII systems, identifying possible interference sources
prior to system design and installation is critically important. The Analyze-R
is the only application specific instrument on the market designed to identify
and record these spectral problems.
Applications The Analyze-R allows you to quickly acquire and document accurate
test measurements for site analysis. Applications
include:
- Verifying geographical site
coordinates and antenna centerline elevations for precise analysis of system
engineering;
- Measuring and documenting the RF
signature of the received signal to capture any possible signal
distortion;
- Measuring and documenting the RF
signature of any potential interfering source;
- Differentiating path-induced problems
from equipment problems;
- Confirming optimum antenna
locations.
First, the
proposed site/antenna location is analyzed by sweeping the band of interest.
This sweep measures possible interfering transmissions within the band and
records their power spectrum. Any one of four ISM/U-NII 100 MHz-wide bands can
be swept and the received signal level power recorded in 1 MHz-wide steps. Then,
once downloaded, this power-to-frequency information is used by site design and
applications engineers to customize radio and antenna design/location to
accommodate interfering signals from other transmissions.
Additionally, the Analyze-R can also
be used by installers to align the sites antenna. By measuring the received
signal level power of the specific frequency being used by the link, the antenna
can be located and adjusted for maximum received signal level and the results
recorded for verification. |