NetFlow
     
shop̿ȳ mypoint ٱ ȸ Ʈ ڷ Q&A ȸҰ
  today :14 total :117960
  Search:    ˻   󼼰˻ Ŭ!  

 

netflow
AKCP ͸
system for Audio-Video
(Power,Relay) IP&
Digital Signage/ȭȸ/
Aiphone
ȭ簨ī޶ ȼַ
Ʈ Extender & Sensors
Lucent
Air station
Panasonic
  ġ : HOME >> ׹ 

Ϲ
Ȯ̹

DataProbe iPIO-8
Ʈ 8port
  ǸŰ
  DataProbe
  걹 USA
  ۱Ⱓ Ȯ 15 ~ 20
 
 ϳ
 ϳ
ɻǰ س ģ ǰõ ٱϿ



    iPIO: Ethernet I/O
     

    Ʈ ϰ, ¸ ͸ Ǵ ִ .

    Web monitoring Inputs and Outputs
    Telnet and SNMP Manageable
    Bringing network management to real-world events
    Romote Response to Physical Events

     

    * о

         . ȯ ͸    . 꼳 ׽Ʈ ý
         . ڵȭ       . Process Control
         . Gate control    . Ethernet I/O Transport
         . ڵȭ ý      . ڵȭ

     

    Application Possibilities

    iPIO is simple to install and easy to use, but enables you to develop highly flexible telemetry systems. 
    We can also work with you to tailor custom and OEM applications for your specific needs.
     

    iPIO - Bidirectional Event Transport

    iPIO gives you the ability to transport digital I/O across Ethernet networks with IP protocols.  Multiple iPIO devices can communicate amongst themselves to transport I/O information across your network, and links are bidirectional, so events in either location are reflected at any other site.  Any changes in status appear at the other end of the network as relay outputs.
     

    iPIO - Network Monitor and Control

    Get real time status updates on you web browser and click to control any relay. Monitor and control digital I/O worldwide using an SNMP V2 compliant manager. iPIO also sends email when events occur.

    iPIO - Multi Site Event Reporting

    One digital input can trigger relay controls at multiple remote locations. With iPIO, one alarm can trigger events throughout your network, making it easy to respond to physical events and manage your systems remotely:

    • Climate Control
    • Industrial Control
    • Security Alerts
    • Firehouse Doors
    • Irrigation Systems
       

    iPIO - Event Consolidation

    Events from multiple locations can also be consolidated to a central alarm point.  Digital inputs from any iPIO unit can be mapped to the relay output of any other, giving you maximum control:

    • Environmental Alarm Summaries
    • Storm Warning Systems
    • Security Alerts
    • Pump Controls
       

     

    iPIO Features:

    Web Controlled Relays

    One click relay control from clear web browser interface. Set name, qualifying time and color scheme for each relay.

    Real Time Status Monitoring

    Continuous updates of input status. No need for browser refresh. Set name and color scheme for each relay

    GPIO Transportation Over the Network

    Send contact closure information across the network to one or multiple places. Get the information you need where you need it.

    Contact Closure via IP

    Manage with SNMP or create your own cuts tom programming to operate relays over the network.

    Link Supervision with Alarm

    Continuously monitors data link between each device and alerts you when the network fails.

    Email Notification

    Receive updates on all input and /or output activity.

    SNMP Management

    SNMP V2c compliant MIB. Integrate into you network management scheme.

    SSL and AES Encryption

    Secure protocols for data integrity and privacy. Prevent unapproved access.

    Wet or Dry Input Monitoring

    Configurable for +VDC inputs 3-30 volts.

    Multi-Site Distribution

    Get status information from one point to multiple locations simultaneously. Ideal for load sheading and security alert notifications.

    Alarm Consolidation

    Summarize multiple alarm points to one location.

    Specifications

    Physical

    iPIO-2

    iPIO-8

    iPIO-16

    Height 1.74" Width 5.63" Depth 3.03" 

    Height 1.25" Width 5.00" Depth 7.32" 

    Height 2.02" Width 5.00" Depth 6.60" 

    Environmental

     

    Temperature 0 - 50 Deg C Operating

    Humidity 90 Pct Non Condensing

    Power

    iPIO-8

    iPIO-16

    iPIO-2

     

    Wall Mounted Power Supply, included

    105 - 240 VAC 50/60Hz or +5VDC direct

    Power over Ethernet (PoE)

    Optional 105 - 240 VAC 50/60Hz or +5VDC direct.

    Inputs

     

     

    iPIO-2

    iPIO-8

    iPIO-16

    Two screw terminals per input.� Dry Contact Closure or

    settable for +3VDC to +30 VDC input, Grounds Common

    2 Inputs

    8 Inputs

    16 Inputs

    Relay Outputs

     

     

     

     

     

     

    iPIO-2

    iPIO-8

    iPIO-16

    Current Maximums 0.5A @ 120VAC or 1A @ 24VDC

    Switching Power 60VA Max 50uW Min

    Switching Voltage 120VAC or 60VDC Max 1VDC Min

    Switching Current 1A Max 1mA Min

    Resistance 100 milliohms (initial value)

    Operations 5 Million, mechanical. 100K at maximum load

    2 Inputs

    8 Inputs

    16 Inputs

    LED Indictors

     

    One LED Indicator for Each Input, Configurable for On or Off state

    One LED Indicator for each Relay Output. Configurable for ON or Off state

    Network Link (Link) and Activity (Act).

    Remote Unit Link Status (Rmt).

    Power (Pwr)

    Switch

     

    Reset. Hardware Reset

    Inputs

     

    8 Digital Inputs

    Dry relay/switch closures or

    +/-3VDC to +/-30 VDC

    Grounds common

    Network

     

    HTTP Web Server

    SSL Secure Sockets Layer

    DHCP Assigned or Static IP Address

    Email to SMTP Server

    SNMP V2 Manageable.

    Inter Device Communications via DxP Protocol

    128 bit AES Encryption optional

    Selectable Port assignments for Web, SSL and DxP Protocol.

     


     
    ǰ󼼺 ȭ ϴ κп µ ޽. Բ ǰȯұ ϰ Ұϴ ϴ.
  • Ϻǰ Ÿ , ǰ ֽϴ.
    쿡 ݺ ҰϿ ֽñ ٶϴ.
  • ǰ ü ̻ 100% ǰ/ȯ/ȯ 帳ϴ.
  • ǰ ڽ Ŀ ǰ/ȯ ʽϴ.

ŬϽø ̴Ͻý ý ȿ ȮϽ  ֽϴ.
÷ο(Netflow) ǥ̻ :  | ڵϹȣ : 220-02-59623 ǸžŰȣ 06825ȣ
ʱ 27 68 202ȣ |
02- 3486-9646  FAX 02-3486-9792
Copyright 2000-2002
÷ο(Netflow) Co.Ltd All rights reserved.

÷ο ŷȸ 2000-1ȣ ǰ, ŷȸ ǥؾ մϴ.